Fluke 1625-2 GEO Earth Ground Tester

FLUKE

Fluke 1625-2 GEO Earth Ground Tester

The Fluke 1625-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1625-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps. This technique eliminates the dangerous, and time consuming job of disconnecting parallel grounds, and finding suitable locations for auxiliary ground stakes. This allows you to perform earth ground tests in places you’ve not considered before, such as inside buildings, on power pylons, or anywhere you don’t have access to soil.

Key features:

• A unique earth ground tester that performs testing with and without stakes

• Tests 3- and 4-pole fall-of-potential, and 4-pole soil resistivity (with stakes)

• Performs selective earth ground rod testing (one clamp + stakes)

• Performs stakeless earth ground rod testing (two clamps)

• Features Automatic Frequency Control (AFC) to minimize the effect of interference

Specifications:

General Specifications
MemoryInternal memory storage up to 1500 records accessible via USB port
Measuring functionInterference voltage and frequency, earthing resistance 3- and 4-pole with/without clip-on current transformer, resistance 2-pole with AC, 2- and 4-pole with DC
Display4 digit (2999 Digit) – 7 segment liquid crystal display, with improved visibility
OperationCentral rotary switch and function keys
Max voltageWarning – socket “clamp” to socket E, ES, S or H
Urms = 0 V
Sockets E, ES, S or H to each other in any combination, max. Urms = 250 V (pertains to misuse)
Quality standardDeveloped, designed and manufactured to comply with DIN ISO 9001
Measurement of Interference Voltage DC + AC (UST)
Measuring limits of error: methodFull wave rectification
Measuring range1 V to 50 V
Display range0.0 V to 50 V
Resolution0.1 V
Frequency rangeDC/AC 45 Hz to 400 Hz sine
Accuracy±(5% of rdg + 5 digit)
Measuring sequenceApprox. 4 measurements/s
Internal resistanceApprox. 1.5 MΩ
Max. overloadUrms = 250 V
Measurement of Interference Frequency (F)
Measuring limits of error: methodMeasurement of oscillation period of the interference voltage
Measuring range6.0 Hz to 400 Hz
Display range16.0 Hz to 299.9 Hz to 999 Hz
Resolution0.1 Hz to 1 Hz
Brand FLUKE
Category Test & Measurement
Request Quote
← Back to Products

Related Products

Fluke 15B+ Digital Multimeter Test & Measurement FLUKE

Fluke 15B+ Digital Multimeter

Unlock professional-grade precision, durability, and safety with the Fluke 15B+ Digital Multimeter. The Fluke…

Fluke 381 Remote Display True RMS AC/DC Clamp Meter with iFlex® Test & Measurement FLUKE

Fluke 381 Remote Display True RMS AC/DC Clamp Meter with iFlex®

Now one technician can do jobs that would otherwise require two people. Clamp the…

Amprobe LM-100 Light Meter Test & Measurement AMPROBE

Amprobe LM-100 Light Meter

The Amprobe LM-100 light meter measures the visible light from fluorescent, metal halide, high-pressure…

Compact Fluke PTi120 Pocket Thermal Camera Test & Measurement FLUKE

Compact Fluke PTi120 Pocket Thermal Camera

Key features: • Automatically organize and file thermal images with Fluke Connect Asset Tagging…