Fluke 1625-2 GEO Earth Ground Tester

FLUKE

Fluke 1625-2 GEO Earth Ground Tester

The Fluke 1625-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1625-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps. This technique eliminates the dangerous, and time consuming job of disconnecting parallel grounds, and finding suitable locations for auxiliary ground stakes. This allows you to perform earth ground tests in places you’ve not considered before, such as inside buildings, on power pylons, or anywhere you don’t have access to soil.

Key features:

• A unique earth ground tester that performs testing with and without stakes

• Tests 3- and 4-pole fall-of-potential, and 4-pole soil resistivity (with stakes)

• Performs selective earth ground rod testing (one clamp + stakes)

• Performs stakeless earth ground rod testing (two clamps)

• Features Automatic Frequency Control (AFC) to minimize the effect of interference

Specifications:

General Specifications
MemoryInternal memory storage up to 1500 records accessible via USB port
Measuring functionInterference voltage and frequency, earthing resistance 3- and 4-pole with/without clip-on current transformer, resistance 2-pole with AC, 2- and 4-pole with DC
Display4 digit (2999 Digit) – 7 segment liquid crystal display, with improved visibility
OperationCentral rotary switch and function keys
Max voltageWarning – socket “clamp” to socket E, ES, S or H
Urms = 0 V
Sockets E, ES, S or H to each other in any combination, max. Urms = 250 V (pertains to misuse)
Quality standardDeveloped, designed and manufactured to comply with DIN ISO 9001
Measurement of Interference Voltage DC + AC (UST)
Measuring limits of error: methodFull wave rectification
Measuring range1 V to 50 V
Display range0.0 V to 50 V
Resolution0.1 V
Frequency rangeDC/AC 45 Hz to 400 Hz sine
Accuracy±(5% of rdg + 5 digit)
Measuring sequenceApprox. 4 measurements/s
Internal resistanceApprox. 1.5 MΩ
Max. overloadUrms = 250 V
Measurement of Interference Frequency (F)
Measuring limits of error: methodMeasurement of oscillation period of the interference voltage
Measuring range6.0 Hz to 400 Hz
Display range16.0 Hz to 299.9 Hz to 999 Hz
Resolution0.1 Hz to 1 Hz
Brand FLUKE
Category Test & Measurement
Request Quote →
← Back to Products

Related Products

Fluke 115 Field Technicians Digital Multimeter Test & Measurement FLUKE

Fluke 115 Field Technicians Digital Multimeter

The Fluke 115 field technician’s digital multimeter measures True-rms voltage and current with plus…

Fluke 51 II Handheld Digital Probe Thermometer Test & Measurement FLUKE

Fluke 51 II Handheld Digital Probe Thermometer

The Fluke 51 II single input digital thermometer delivers fast response with laboratory accuracy…

Amprobe TMA5 Mini Vane Anemometer Test & Measurement AMPROBE

Amprobe TMA5 Mini Vane Anemometer

The Amprobe TMA5 Mini Vane Anemometer is a compact, pocket-sized tool for indoor air…

Fluke 930 Non-Contact Tachometer Test & Measurement FLUKE

Fluke 930 Non-Contact Tachometer

Fluke 930 is a handheld tachometer and is equivalent to a Fluke 931 with…